One Metric Guides Them All
What if I told you that one metric, with a sometimes questionable source, was guiding the decisions and lives of millions of people? If that one metric was generated by multiple hardware vendors, and as each year passes, the vendors try and squeeze juice from the pith of that metric in an attempt to add value to their products?
That metric is heart rate. HR, in wearable technology concepts, comes from two sources: a 1-lead ECG in the form of a chest strap, or an optical HR sensor.
Now I want to make it clear: I know other data is captured for background wellness, primarily motion and temperature, but the primary input is oHR.
Edit: a couple of days after publishing, my partner, who was feeling a bit ill, called form the bedroom 'my Apple Watch just told me my pulse ox was 94%!' This wasn't taken from an intentional, at-rest reading, but one the algo had deemed acceptable. When we put a Masimo Mightsat on their finger, it reported 98%. Anecdotal, but Fortuna timed it well.
oHR?
Optical HR, or reflectance photoplethysmography to its friends, attempts to glean your HR by shining light from LEDs through the skin, detecting blood volume changes in the microvascular bed of tissue.
Or, a small torch and camera are held next to your skin: the light illuminates the underlying tissue, and a computer interprets HR data from the image. At rest, this works well, producing (I think) universally-agreed upon decent results, allowing inference of not just heart rate, but R-R intervals and heart-rate variance (how much your individual heart beats vary from each other, with the loose understanding that more variance = more rested).
In motion, however, this becomes problematic. As when someone knocks your arm as you take a photo, and the image is streaked, if the oHR reader does not move in perfect harmony with the measuring site, it produces bad data. Coupling an accelerometer's data with the oHR data allows post-processing to discard oHR values that are likely to be poor.
If this wasn't bad enough, and I'm going to pull a quote from 2017 here:
"The wrist is about the worst place on the body to get an accurate measurement,"
This is from Dr. Steven LeBeouf: https://www.wareable.com/fitness-trackers/measuring-heart-rate-from-wrist-ears-head-320
“The sheer number of bones, tendons and muscle create higher optical noise in the wrist.”

Valencell is (was? their website has been offline since 2026-06) a US biometric technology company founded in 2006 in Raleigh, North Carolina, by Dr Steven LeBoeuf, Dr Jesse Tucker and Dr Mike Aumer. It specialises (specialised?) in oHR, developing optical sensors, signal-processing algorithms and reference-validation methods for physiological measurements in wearable devices.
Sure, this was 10 years ago, and we have better hardware across the entire data generation path than then, but the fundamental problems of physics still remain.
We're trying to read fine-print text through a doily that's dancing in the breeze.
I mention it because of the preponderance of devices generating data from the back of a watch, or in Whoop's case, a sensor often worn on the wrist.
There's another problem common to oHR, too: a phenomenon called cadence lock. When walking or running, the signal processing can see the regular jolt caused by our feet impacting the ground, and interpret that as HR. I saw this a couple of weeks ago (2026-10-15 1130, ~20ºC), using a Polar Verity Sense on my bicep: whilst running my HR was shown as ~82bpm, essentially the same as my cadence. As soon as I power-cycled the sensor, the problem resolved:

Now you'll notice I included temperature in my chronological coordinates: this is the final piece of mud I'll sling at the much-maligned sensor. On a cold day, we undergo vasoconstriction, reducing the observable tissue change, which makes it even harder to acquire signal.
The metrics produced from the oHR sensor
| Metric | Output | Classification | External data required? | Method / Requirements | Maturity |
|---|---|---|---|---|---|
| Heart rate (HR) | beats/min | Calculated | No | Pulse frequency or beat detection | Established |
| Interbeat interval (IBI / PPI) | ms | Calculated | No | Time between consecutive optical pulse landmarks | Established |
| Pulse rate variability (PRV) | ms | Calculated | No | Variability in successive pulse intervals | Established |
| PRV: RMSSD | ms | Calculated | No | Root mean square of successive pulse interval differences | Established at rest |
| PRV: SDNN | ms | Calculated | No | Standard deviation of normal pulse intervals | Established at rest |
| PRV: pNN50 | % | Calculated | No | Percentage of successive normal pulse intervals differing by more than 50 ms | Conditional |
| PRV: LF/HF spectral power | ms², ratio | Calculated | No | Frequency-domain analysis of pulse intervals | Conditional; physiological interpretation disputed |
| Pulse amplitude | Relative units | Calculated | No | PPG peak-to-trough amplitude | Established |
| Perfusion index (PI) | %, ratio | Calculated | No | Ratio of pulsatile to non-pulsatile optical signal | Established |
| Pulse morphology | Waveform features | Calculated | No | Rise time, width, slope, dicrotic notch and derivatives | Established |
| Resting heart rate | beats/min | Calculated | Yes: activity/rest classification | HR measurements during identified resting periods | Established |
| Sleeping heart rate | beats/min | Calculated | Yes: sleep-state classification | HR measurements during identified sleep periods | Established |
| Heart rate recovery (HRR) | beats/min | Calculated | Yes: exercise termination timestamp | Difference between HR at exercise cessation and subsequent recovery intervals | Established |
| Heart rate zones | Zone / % HRmax | Calculated | Yes: individual HR thresholds | HR compared against predefined or individually measured thresholds | Established |
| Pulse arrival time (PAT) | ms | Calculated | Yes: synchronised ECG | Time between ECG reference event and peripheral pulse arrival | Established |
| Pulse transit time (PTT) | ms | Calculated | Yes: synchronised second pulse measurement | Time between arterial pulse landmarks at two locations | Established |
| Pulse wave velocity (PWV) | m/s | Calculated | Yes: pulse transit time and estimated vascular path length | Estimated distance divided by pulse transit time | Established method; measurement-dependent |
| Respiratory rate | breaths/min | Inferred | No | Respiratory modulation of pulse amplitude, baseline and frequency | Established under suitable conditions |
| Peripheral oxygen saturation (SpO₂) | % | Inferred | No; requires suitable red/infrared optical channels | Calibrated ratio-of-ratios optical absorption model | Established with validated hardware |
| Arrhythmia screening | Probability / classification | Inferred | No | Pulse irregularity, morphology and classification algorithms | Established for selected applications |
| Arterial stiffness indices | Index / relative units | Inferred | No | Pulse-wave morphology and reflected-wave characteristics | Research / conditional |
| Vascular ageing | Modelled age / index | Inferred | Yes: population reference model | Pulse morphology and arterial stiffness proxies | Experimental |
| Autonomic arousal | Relative index | Inferred | No | PRV and haemodynamic changes interpreted through a physiological model | Indirect, model-dependent |
| Blood pressure estimation | mmHg | Inferred | Conditional: calibration, reference BP or additional sensors | Pulse morphology, timing and predictive models | Experimental / device-dependent |
| Blood pressure trends | mmHg / relative change | Inferred | Conditional: calibration or additional sensors | Longitudinal PPG features interpreted through a calibrated model | Experimental / device-dependent |
| Training load | Arbitrary units | Inferred | Yes: exercise duration, intensity thresholds and personal model | Integration of HR intensity and duration | Model-dependent |
| VO₂max estimation | mL/kg/min | Inferred | Yes: exercise speed/power, individual characteristics and model | Cardiovascular response mapped to estimated aerobic capacity | Model-dependent |
| Energy expenditure | kcal | Inferred | Yes: movement, individual characteristics and calibration | HR and activity features mapped to estimated metabolic expenditure | Model-dependent |
| Sleep staging | Wake / N1 / N2 / N3 / REM | Inferred | Conditional: accelerometry, temperature or other signals | Classification of PPG-derived HR/PRV and supplementary signals | Model-dependent |
| Sleep apnoea screening | Events/hour / risk score | Inferred | Conditional: movement or additional respiratory signals | SpO₂ patterns, pulse variability and respiratory modulation | Device-dependent |
| Stress score | Index / arbitrary units | Inferred | Conditional: activity, baseline and personal model | PRV and HR features interpreted through a stress model | Model-dependent |
| Recovery score | Index / arbitrary units | Inferred | Yes: sleep/activity history and individual baseline | PRV, resting HR, sleep and longitudinal physiological modelling | Model-dependent |
If you glossed over the table, that's 32 - XXXII - metrics from a sensor with established problems, shipped in devices from Apple, Samsung, Google, Garmin, Whoop, Ōura, Suunto, Coros, Polar, Amazfit, Fitbit &c. Every day these devices can tell their wearers 'this is how you are today!' And every day people use these to inform their life choices: how hard should they go today? How easy? Are they well?
The cost
In my earlier post, Evolving Nunc, I posited that re-training myself to ask how I was today, compared to yesterday, to be the most powerful signal. Every day, for probably the last nine years or so, I have been trained to not listen to my body, but instead listen to data from a questionable source with known defects.
I'm happy to say that, for me, this reign of cousining has ended, but how many other people are blindly acting on their devices suggestions for the day?
A reminder, in closing: this isn't a bad technology. This technology can produce satisfactory data both at rest, and in motion, but I feel it is a much-abused technology, like someone using a shopping trolley exhumed from a canal as a bobsleigh. A technology relied upon to provide market differentiation at the cost of accurate health intelligence.
So, where do we go from here? I'll be writing another post on appropriate sensors for the purpose, and who lets us correct the garbage in/garbage out problem created by this abuse.